BRT LB78 Precision signal generator covers most functions required for maintenance of PLC, DCS, ESD, field instrument, regulating valve and frequency changer, and it has long-term stability and high precision. It can generate dc current signal active or passive 0-24mA, voltage signal 0-11VDC, mV small signal 0-110mV, 24V, etc. It is characterized by safety protection design in every aspect and clear LED screen display, and adopts a flame-retardant shell, refined anti-scratch cover. Handheld pocket size makes it is easy to carry.

Discount per Quantity

QuantityDiscountPrice
2 - 55.5%$47.20
6 - 108.5%$45.70
11 - 2011%$44.46

Description

BRT LB78 Signal generator is a high precision reliable low-cost 0-24mA sink and source signal simulator generator, 0-11V 0-110mV mV signal generator, 24V signal simulator instrument. Only five buttons to adjust output signal, large capacity battery inside, LED accurately display, user-friendly design, it becomes an essential debugging tool in industrial signal calibrations and debugging applications.

Main Features
• Pocket size shell with testing clips, external size: 108x66x20mm (L x W x H).
• Reliable 0-11V, 0-24mA source or sink signal, 0-110mV, 24V output, accurate LED display.
• Fast response and zero delay once pressing the buttons.
• Low power dissipation, 2200mAH re-chargeable battery inside, long stand-by time.
• Simple key layout, all functions have independent corresponding keys, simple easy-to-use.
• Built-in one-time quick-break fuse can avoid instrument damages caused in case of connecting probes to electric supply with 110V or 220V.
• Using reliable precision DA, reference voltage and operational amplifier chips to improve temperature stability and long-term performance.
• Operating temperature range: -10-+50℃, 20–80%RH humidity, non-condensation.
• Save cost and energy in the labs or outdoor industrial site.

Technical Parameters

FUNCTION UNITOUT RANGESET STEPSACCURACY/ERROR
DC. VoltageV0~11.00V0.01/0.1/10.01 V
DC. mV VoltagemV0~110.00mV0.1/1/100.1 mV
DC Current mA (source, sink)mA0~24.00mA0.01/0.1/1/4 0.01 mA
24V24V
mA
0~24.0 mANone 0.2 mA

LB78 mA V mV Signal Generator Testing Show


Set Changing Steps
V, mA, mV buttons are both functional setting buttons and stepping setting buttons. When the generator is in one function status (e.g.: V/mV/mA output), press its corresponding functional button (e.g.: V/mV/mA button), user can access to changing step setting status (e.g.: V/mV/mA step setting). Then step setting byte is on, the other byte is off; next press this button again to change step setting byte.

E.g.: Change V output steps: first press V button to access to V output status, then press V button again to enter into changing steps setting status; after that the setting step byte is on;
Next, press V button again to set the changing step into 0.01V or 0.1V or 1.0V.

V output changing steps available: 0.01/0.1V/1.0V
mV output changing steps available: 0.01/0.1V/10.0mV
Note: mA output step setting: 0.01/0.1/1.0/4.0 mA
1.0 mA and 4.0mA steps are in same byte position, if the step setting value is 1.0, this byte will be on, other bytes are off; if step setting value is 4.0, this byte position is still on, and others are off, but the figure shown is “4”.

Voltage or mV Signal Output
There are three LED indicators in corresponding to V, mA, mV buttons, if the LED indicator above V/mV button is not on, press V/mV button to access to voltage output function. Press ↓ and  buttons to increase and decrease output signal value. By referring to set changing steps above, user can increase and decrease voltage accordingly.

mA Current Source 24V Signal Output
Current output function has three sub-functions: active current output (screen displays SOU), passive current output (screen displays SIN), 24V output (screen displays 24 U) output.
Long press mA button to switch among these three functions alternatively. Long press mA button one time to switch one function and cannot be continuous shifted to next function.
For example, if user wants to shift from active current output function to 24V output function, user has to long you press button for 3 times.
The operation methods of active current and passive current output are similar to those of voltage and mV.

Typical Applications

mA Current Generator and Simulator
0-20mA 4-20mA Output Simulation
0-75mV, 0-10V Voltage Simulator Generator
0-5V 0-10V mV Voltage Signal Output Simulation
24V Analog Simulator Generator
24V Output Simulation

*Please download data sheet to get details.

Download Now:

BRT LB78 Signal Generator User Manual

Additional information

Weight0.6 kg
Dimensions10.8 × 6.6 × 2.0 cm
Output Signal

0-24mA source and sink signal, 0-11V, 24V, 0-110mV signal.

Packing List

1 Unit x Original LB78 Signal Generator
1 Piece x USB power cable
1 Piece x High quality portable protection meter bag
1 Set x Professional User Manual Paper version

Why Choose Us?

Securely shopping without any Paypal/bank charge! Get credit points, get amazing discount price by Registering Your Account! Buy with confidence!

-100% original Premium version only.
-Fast shipping.
-More than 5 years experience.
-Factory direct price and quality.
-Professional user manual.
-Various full range.
-MOQ 1 unit.
-24 months warranty and technical support service.
-Protect your privacy, no spam email.
-Support credit card, Visa, Matercard online payment.

How to Buy?

-Confirm quantity —-> Click Button" Add to cart" —-> then Button "View cart"—->go next step accordingly and pay via Credit Card, Visa, Master Card, AE, Paypal online.
-Or Pay it via Bank wire transfer T/T, please contact us to get our bank information.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

You may also like…